The Canon CXDI-801C Wireless Digital Radiography System is designed to help healthcare professionals attain a high level of performance, usability, and reliability in a lightweight, compact form. By utilizing technology and solutions that help accelerate exams and maintain productive workflow, practitioners can effectively accomplish more while providing quality care. In X-ray auto detection mode, this DR system can detect X-rays at exposure and shift to image acquisition mode automatically without the use of a typical generator interface. The CXDI-801C Wireless System builds upon the successful CXDI-80C Wireless DR System with its high-quality image sensors that provide high-resolution images at a low X-ray dose, and incorporates more customer-focused features, such as enhanced liquid intrusion protection, battery charging while in the detector with a wired option (sold separately), and impact detection. The CXDI 801C Wireless DR System is light and easy to handle, weighing only 5.1 pounds (with battery). This cassette-size detector has an approximate 11 x 14 inch imaging area, and is useful for a wide range of patients, including infants in the Neonatal Intensive Care Unit (NICU).

Features

  • High Resolution and High Sensitivity:
    With a 125 micron pixel pitch, the CXDI-801C Wireless Digital Radiography (DR) System delivers exceptional spatial resolution. The high sensitivity of the Cesium Iodide (CsI) scintillator helps reduce the X-ray exposure to the patient. The maximum 3 second exposure time allows this digital detector to be used with tomography equipment and for other exams that may require an exposure time of up to 3 seconds.
  • Portable and Flexible:
    The CXDI-801C Wireless DR System may be used in multiple x-ray rooms. Simply "check in" the digital detector in the computer. The Infrared (IR) Communication module makes it easy to switch detectors among the systems. For easy transport, an optional handle is available.
  • Wireless Range:
    The wireless communication may be set for applicable strength, and, depending on the room where the CXDI-801C Wireless DR System is used, the power can be managed. Should the wireless connection be lost, the unit will automatically attempt to reconnect and to prevent image loss. Acquired images are stored locally in the on-board memory. Once reconnected, the images can be retrieved. An optional wiring unit allows images to be transferred from a panel mounted in a Bucky tray to the control computer over hard wire.
  • 5 GHz for Fast Data Transfer:
    The CXDI-801C Wireless DR Detector runs at 5 GHz and 2.4 GHz on an 802.11n network that increases signal clarity - resulting in fast data transfer speed.
  • Battery:
    The battery lasts up to 6.5 hours and takes less than 3 hours to charge. The battery can be charged in the unit with the wired option (sold seperately). An accessory battery charger (sold separately) can additionally charge up to 2 batteries at a time so a fresh battery can be continuously available. The control console includes a battery indicator for image count and power level monitoring. Additional batteries (sold separately) are also available.
  • CXDI Control Software NE:
    The CXDI-801C Wireless DR System uses the Canon CXDI Control Software NE. The software gives a wide range of selections and images can be taken with three touches. An on-screen preview image is available approximately 1-2 seconds after exposure. The image processing shows subtle details of trabecular bone structure and soft tissue in the same image. For more information, visit our CXDI Control Software NE webpage. 
Additional Information

Additional Information

More Information

Detector

 

Method

Cassette Size Detector, Scintillator & Amorphous Silicon (a-Si)

 

Scintillator

Csl (Csl: TI)

 

Sensor

LANMIT (Large Area New-MIS sensor and TFT)

 

Pixel Pitch

125 Microns

 

Pixels

2,192 x 2,800 Pixels (6.1 Megapixels)

 

Imaging Area

Approximately 11 x 14 in (27.4 x 35 cm)

 

Standard Configuration

Sensor Unit, X-Ray Interface Box, Battery Charger, Detector Check-In Unit, Wireless Access Point (Including A/C Power)

 

Battery

 

Life

Up to 6.5 Hours

 

Recharge Time

Less Than 3 Hours

 

Performance

Approximately 140 Images

 

Image Acquisition and Processing

 

Image Processing

Standard Advanced Multi-Frequency Processing

 

A/D

16-bit

 

Grayscale Output

12 bit or 16 bit Selectable

 

Preview Image

Approximately 1-2 Seconds After X-ray Exposure

 

Full Image Display

Approximately 5-6 Seconds After X-ray Exposure

 

Data Output and Network Connection

 

Wireless Standard

IEEE 802.11n (5 & 2.4 GHz)

 

DICOM

DICOM 3.0 Compatible, Print Management (SCU), Storage (SCU), MWL (SCU), MPPS (SCU)

 

Electrical and Environmental

 

Operating Environment

Sensor unit: 41-95°F (5-35°C), Humidity 30-80% RH (non-condensing)

 

Physical Characteristics

 

Dimensions (W x L x H)

12.1 x 15.1 x 0.6 in (307 x 384 x 15 mm)
(Detector unit only)

 

Weight

5.1 lbs (2.3 kg) (with battery)

 

 

 

Specifications are subject to change without notice.