Contact us at (800) 635-9729


Need Radiology Supplies ?     CLICK HERE

AGFA CR DX-M

AGFA CR DX-M
AGFA CR DX-M is the next generation CR system for digital mammography and general radiography. It provides excellent image quality.
Description

Details

The DX-M is used in the radiography department, supporting digital mammography and general radiography. The DX-M supports both standard phosphor plates and needle-based detectors. It has a user-friendly drop-and-go buffer that can handle a mix of mammography and general radiography cassettes as well as a mix of five cassettes of different sizes of both needle-based detectors and standard phosphor plates. The drop-and-go buffer and fast preview eliminate waiting times which provides a smooth workflow.
Additional Information

Additional Information

Specifications

GENERAL

Drop-and-go cassette buffer

5 cassettes of mixed sizes input buffer and 5 cassettes of mixed sizes output buffer

Throughput

35 x 43 cm (14 x 17 in) = approx. 83 plates/hour

Display for status and error indication

• LCD touchscreen

• LED status indicator

Greyscale resolution

• Output to processor: 16 bits/pixel square root compressed

Dimensions and weight

• Covered floor space: (W x D x H): 66 x 51 x 123 cm (26 x 20 x 48.4 in)

• Output buffer included: (W x D x H): 115 x 51 x 123 cm (43.5 x 20 x 48.4 in)

• Weight: approx.: 180 kg (397 lbs)

Configuration requirements

• NX

• ID tablet

• CR HD5.0 Detectors and Cassettes

• CR MD4.0R Plates and Cassettes

• Either CR HM5.0 MAMMO Detectors and Cassettes

Power

• 220 - 240 V/50-60 Hz Standby 87 W, peak 590 W, fuse 16 A

• 120 V/60 Hz (USA) Standby 92 W, peak 621 W, fuse 15 A

• 100 V/60 Hz (Japan) Standby 92 W, peak 621 W, fuse 15 A

Environmental conditions DX-M digitizer

• Temperature: 15 - 30˚ C (59 - 86˚ F)

Temperature: for use with CR HM5.0 MAMMO Detector: 20 - 30˚ C (68 - 86˚ F)

• Humidity: 15 - 75 % RH

• EMC compliant with IEC 60601-1-2

• Rate of change of temperature: 0.5˚ C/minute (0.9˚ F)

Environmental effects

• Noise level: max. 65 dB (A)

• Heat dissipation: standby 92 W, continuous operation 242 W

SAFETY

Approvals

• ETL classified CUS, CE

Transport details

• Temperature: -25 to +55˚ C (-13 to 131˚ F), -25˚ C for max. 72 hours, +55˚ C for max. 96 hours

• Humidity: 5 - 95 % RH

Cassette Feed No
Throughput No
Grayscale Resolution No
Display No
Dimensions No
Weight of Equipment No
Operating Conditions No
Noise Level No
Power No
Transport Details No
Safety No
REQUEST QUOTE

Personal Info

  • all numbers no dashes

Company Information

Product Information

* Required Fields